• Transfer Pump Controller: PM-021N-T is a Transfer Pump
Controller for controlling the operation of 2 to 4 water pumps.
• Can check water levels for Water Well (3 levels) and Water
Tank (4 levels) for use.
• Level sensors supported: Electrode / Float Switch / Pressure Switch.
• Has Latching Function with Memory to store values during
power failure for alternating the operation of each pump.
• Has DIP Switch to disconnect a pump from the system in
case one pump is faulty or overloaded, and allow another
pump to operate instead.
• Has Reinforce Operation to increase the number of operating
pumps when the water level in the system drops significantly.
• Alarm Output for various abnormalities.
• Over and Under Voltage Protection: the controller will stop
operating if the supply voltage is outside the set range (for models with
Voltage Protection).
• 3 Phase System: Over and Under Voltage, Phase Sequence,
Phase Loss, range 80–120% of nominal voltage.
• RS-485 Modbus RTU Protocol communication for connection to a
computer.
• Has a delay time to allow the pump to operate for at least 0 or 5
seconds to prevent frequent on/off switching.
• Has a continuous operation time limit of 1 or 3 hours
(to prevent one pump from operating too long by switching to
another pump).
• Has Flow Switch input to check water flow in the system to
prevent Dry Run.
• Has Overload input: when any pump is overloaded, that pump is
disconnected from the system and bypassed so another pump can
operate instead.
• LED indicators show the status of Output, Level, and Alarm.
• LED indicators show the status of Level Sensor Fault.
PM-021N-T is a device that can control water pumps to draw water from the Water Well and deliver it to the Water Tank. There are 2 models available: the 2-pump model and the 3-pump model. The operation alternates each pump so that the operating hours of each pump are close to each other.
• Transfer Pump Controller: PM-021N-T is a Transfer Pump
Controller for controlling the operation of 2 to 4 water pumps.
• Can check water levels for Water Well (3 levels) and Water
Tank (4 levels) for use.
• Level sensors supported: Electrode / Float Switch / Pressure Switch.
• Has Latching Function with Memory to store values during
power failure for alternating the operation of each pump.
• Has DIP Switch to disconnect a pump from the system in
case one pump is faulty or overloaded, and allow another
pump to operate instead.
• Has Reinforce Operation to increase the number of operating
pumps when the water level in the system drops significantly.
• Alarm Output for various abnormalities.
• Over and Under Voltage Protection: the controller will stop
operating if the supply voltage is outside the set range (for models with
Voltage Protection).
• 3 Phase System: Over and Under Voltage, Phase Sequence,
Phase Loss, range 80–120% of nominal voltage.
• RS-485 Modbus RTU Protocol communication for connection to a
computer.
• Has a delay time to allow the pump to operate for at least 0 or 5
seconds to prevent frequent on/off switching.
• Has a continuous operation time limit of 1 or 3 hours
(to prevent one pump from operating too long by switching to
another pump).
• Has Flow Switch input to check water flow in the system to
prevent Dry Run.
• Has Overload input: when any pump is overloaded, that pump is
disconnected from the system and bypassed so another pump can
operate instead.
• LED indicators show the status of Output, Level, and Alarm.
• LED indicators show the status of Level Sensor Fault.