• Digital AC Volt Meter (True RMS) / Digital DC Volt Meter (True RMS): TCM-94N Series
is designed to measure and indicate voltage results.
• The alternating current (AC) electrical system has a measured voltage range of 5–500 VAC (direct),
0.5–100.0 VAC (direct), and 0–20,000 VAC (with PT) at a frequency of 50–60 Hz.
• The direct current electrical system(DC) measured voltage rage 0-500VDC (Direct).
• Can set the multiplier depend on PT Ratio when it connect with
Potential Transformer(PT) of High Voltage system.
• 3 Alarm Relay Output with 4 alarm functions for setting.
• Communicate with computer via RS-485 Modbus RTU PROTOCOL.
• Transfer Output 4-20 mA and 0-10 VDC.
• Manual Transfer Output function can supply signal volume as
required by keypad.
• Absolute Input Function show positive value all the time even
the connect input node +/- alternated position for TVM-94N-2.
• Function Peak Hold shows maximum voltage value.
• 7-Segment 5 digits size 0.56 inches display so it can display
the maximum voltage value.
• Lock Function to block the screen setting.
• ON-OFF Delay Time for Alarm Output.
Digital AC Volt Meter (True RMS) / Digital DC Volt Meter (True RMS) : TCM-94N-Series is an electrical voltage meter for alternating current (AC) and direct current (DC) system. The device has AC voltage range 5-500VAC (DIRECT), 0.5-100.0VAC (DIRECT), 0-20,000VAC (With PT) at 50-60 Hz and DC voltage range 0-500VDC (DIRECT). User can set multiplied by PT ratio when connect with Potential Transformer (PT) of High Voltage. It can communicate with computer by RS-485 Modbus RTU PROTOCOL.
• Digital AC Volt Meter (True RMS) / Digital DC Volt Meter (True RMS): TCM-94N Series
is designed to measure and indicate voltage results.
• The alternating current (AC) electrical system has a measured voltage range of 5–500 VAC (direct),
0.5–100.0 VAC (direct), and 0–20,000 VAC (with PT) at a frequency of 50–60 Hz.
• The direct current electrical system(DC) measured voltage rage 0-500VDC (Direct).
• Can set the multiplier depend on PT Ratio when it connect with
Potential Transformer(PT) of High Voltage system.
• 3 Alarm Relay Output with 4 alarm functions for setting.
• Communicate with computer via RS-485 Modbus RTU PROTOCOL.
• Transfer Output 4-20 mA and 0-10 VDC.
• Manual Transfer Output function can supply signal volume as
required by keypad.
• Absolute Input Function show positive value all the time even
the connect input node +/- alternated position for TVM-94N-2.
• Function Peak Hold shows maximum voltage value.
• 7-Segment 5 digits size 0.56 inches display so it can display
the maximum voltage value.
• Lock Function to block the screen setting.
• ON-OFF Delay Time for Alarm Output.